Datasheet


  
    
SLVS323B − FEBRUARY 2001 − REVISED JANUARY 2007
2
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Ĕ
Input voltage range    0.3 V to 13.5 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage range at EN
−0.3 V to V
I
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Voltage on OUT, FB 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Peak output current Internally limited. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ESD rating, HBM 2 kV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature range, T
J
−40°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to network ground terminal.
DISSIPATION RATING TABLE
BOARD
PACKAGE R
θJC
R
θJA
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
25°C
POWER RATING
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
Low K
DBV 65.8°C/W 259°C/W 3.9 mW/°C 386 mW 212 mW 154 mW
High K
§
DBV 65.8°C/W 180°C/W 5.6 mW/°C 555 mW 305 mW 222 mW
The JEDEC Low K (1s) board design used to derive this data was a 3 inch x 3 inch, two layer board with 2 ounce copper traces on top of the board.
§
The JEDEC High K (2s2p) board design used to derive this data was a 3 inch x 3 inch, multilayer board with 1 ounce internal power and ground
planes and 2 ounce copper traces on top and bottom of the board.
recommended operating conditions
MIN NOM MAX UNIT
Input voltage, V
I
(see Note 2) 2.7 10 V
Output voltage range, V
O
0.7 5.5 V
Continuous output current, I
O
(see Note 3) 0.01 100 mA
Operating junction temperature, T
J
−40 125 °C
NOTES: 2. To calculate the minimum input voltage for your maximum output current, use the following formula:
V
Imin
= V
Omax
+ V
DO
(max load)
3. Continuous output current and operating junction temperature are limited by internal protection circuitry, but it is not recommended
that the device operate under conditions beyond those specified in this table for extended periods of time.