User manual

www.ti.com
2.1.2 J2 GND
2.1.3 JP1 Bank-A Enable
2.1.4 JP2 Bank-B Enable
2.1.5 JP3 LED D1A Cathode Connection
2.1.6 JP4 LED D2A Cathode Connection
2.1.7 JP5 LED D2B Cathode Connection
2.1.8 JP6 LED D1B Cathode Connection
2.2 Setup
2.2.1 EVM Factory Configuration
Setup
This is the input return connection for the input power supply.
JP1 is used to enable the bank-A LEDs. Place a shorting bar in the ON position to turn on the bank-A
LEDs. When the bank-A LEDs are enabled, the LED current through LEDs D1A and D2A is regulated to
the value programmed at ISET (5 mA). Place a shorting bar in the OFF position to turn off the bank-A
LEDs.
JP2 is used to enable the bank-B LEDs. Place a shorting bar in the ON position to turn on the bank-B
LEDs. When the bank-B LEDs are enabled, the LED current through LEDs D1B and D2B is regulated to
the value programmed at ISET (5 mA). Place a shorting bar in the OFF position to turn off the bank-B
LEDs.
JP3 is used to measure the current through LED D1A. Place a current meter between the pins of JP3 to
measure the current. Alternatively, a resistor can be connected between the pins of JP3 in order to
measure the current as a voltage. Place a shorting bar across the pins of JP3 if current measurement is
not required. PCB pads are provided to install a current-sense resistor across this jumper.
JP4 is used to measure the current through LED D2A. Place a current meter between the pins of JP4 to
measure the current. Alternatively, a resistor can be connected between the pins of JP4 in order to
measure the current as a voltage. Place a shorting bar across the pins of JP4 if current measurement is
not required. PCB pads are provided to install a current-sense resistor across this jumper.
JP5 is used to measure the current through LED D2B. Place a current meter between the pins of JP5 to
measure the current. Alternatively, a resistor can be connected between the pins of JP5 in order to
measure the current as a voltage. Place a shorting bar across the pins of JP5 if current measurement is
not required. PCB pads are provided to install a current-sense resistor across this jumper.
JP6 is used to measure the current through LED D1B. Place a current meter between the pins of JP6 to
measure the current. Alternatively, a resistor can be connected between the pins of JP6 in order to
measure the current as a voltage. Place a shorting bar across the pins of JP6 if current measurement is
not required. PCB pads are provided to install a current-sense resistor across this jumper.
The EVM is configured to provide the following nominal operating conditions:
Input voltage: 2.5 V to 5.5 V
LED current: 5 mA
TPS75105EVM 2 SLVU182 September 2006
Submit Documentation Feedback