Datasheet

2-2
EVM Test Setup
The settings for the test equipment shown in Figure 21 are described below:
- Function generator is set to a triangle wave that ramps from 0 V to 8 V, and
a period of 10 ms.
- Power amplifier is set to a gain of 3 dB and a minimum slew rate of 5000
V/µs.
- Power supply capable of ±30-V swing and a 0.5-A current limit to power
the power amplifier.
- A four-channel oscilloscope with channel ones voltage probe connected
to J1 (IN) and channel twos voltage probe connected to J3 (OUT). Using
a free channel, connect a current probe around the output load resistance.
Set the scope to trigger off of channel one so that one full triangle is
displayed on the screen.
- A 66- resistance for 50-mA of output current (or 50-mA electronic load)
connected between J3 (OUT) and J2 (GND).
After powering on the amplifier, the input voltage, output voltage, and output
current is displayed.