Datasheet

TPS71025
LOW-DROPOUT VOLTAGE REGULATOR
SLVS162A – MAY 1997 – REVISED MAY 1998
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Input voltage range, V
I
, EN (see Note 1) 0.3 V to 11 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current, I
O
2 A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Tables 1 and 2. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature range, T
J
–0°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to GND
DISSIPATION RATING TABLE 1 – FREE-AIR TEMPERATURE
PACKAGE
T
A
25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 125°C
POWER RATING
D 725 mW 5.8 mW/°C 464 mW 145 mW
P 1175 mW 9.4 mW/°C 752 mW 235 mW
PW 700 mW 5.6 mW/°C 448 mW 140 mW
DISSIPATION RATING TABLE 2 – CASE TEMPERATURE
PACKAGE
T
C
25°C DERATING FACTOR T
C
= 70°C T
C
= 125°C
PACKAGE
C
POWER RATING ABOVE T
C
= 25°C
C
POWER RATING
C
POWER RATING
D 2188 mW 17.5 mW/°C 1400 mW 438 mW
P 2738 mW 21.9 mW/°C 1752 mW 548 mW
PW 4025 mW 32.2 mW/°C 2576 mW 805 mW
Dissipation rating tables and figures are provided for maintenance of junction temperature at or below
absolute maximum temperature of 150°C. For guidelines on maintaining junction temperature within
recommended operating range, see the Thermal Information section.
recommended operating conditions
MIN MAX UNIT
Input voltage, V
I
2.97 10 V
High-level input voltage at EN, V
IH
2 V
Low-level input voltage at EN, V
IL
0 0.5 V
Output current range, I
O
0 500 mA
Operating virtual junction temperature range, T
J
0 125 °C