Datasheet
TPS70245, TPS70248
TPS70251, TPS70258
TPS70202
www.ti.com
SLVS286E –JUNE 2000–REVISED DECEMBER 2009
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
ORDERING INFORMATION
(1)
VOLTAGE (V)
(2)
PACKAGE- SPECIFIED
LEAD TEMPERATURE ORDERING TRANSPORT
PRODUCT V
OUT1
V
OUT2
(DESIGNATOR) RANGE (T
J
) NUMBER MEDIA, QUANTITY
TPS70202PWP Tube, 70
TPS70202 Adjustable Adjustable HTSSOP-20 (PWP) -40°C to +125°C
TPS70202PWPR Tape and Reel, 2000
TPS70245PWP Tube, 70
TPS70245 3.3V 1.2V HTSSOP-20 (PWP) -40°C to +125°C
TPS70245PWPR Tape and Reel, 2000
TPS70248PWP Tube, 70
TPS70248 3.3V 1.5V HTSSOP-20 (PWP) -40°C to +125°C
TPS70248PWPR Tape and Reel, 2000
TPS70251PWP Tube, 70
TPS70251 3.3V 1.8V HTSSOP-20 (PWP) -40°C to +125°C
TPS70251PWPR Tape and Reel, 2000
TPS70258PWP Tube, 70
TPS70258 3.3V 2.5V HTSSOP-20 (PWP) -40°C to +125°C
TPS70258PWPR Tape and Reel, 2000
(1) For the most current package and ordering information see the Package Option Addendum located at the end of this document, or see
the TI web site at www.ti.com.
(2) For fixed 1.20V operation, tie FB to OUT.
ABSOLUTE MAXIMUM RATINGS
(1)
Over operating free-air temperature range (unless otherwise noted).
TPS702xx UNIT
Input voltage range: V
IN1
, V
IN2
(2)
–0.3 to +7 V
Voltage range at EN1, EN2 –0.3 to +7 V
Output voltage range (V
OUT1
, V
SENSE1
) 5.5 V
Output voltage range (V
OUT2
, V
SENSE2
) 5.5 V
Maximum RESET, PG1, PG2 voltage 7 V
Maximum MR voltage V
IN1
V
Peak output current Internally limited —
Continuous total power dissipation See Dissipation Ratings Table —
Operating virtual junction temperature range, T
J
–40 to +150 °C
Storage temperature range, T
stg
–65 to +150 °C
ESD rating, HBM 2 kV
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are tied to network ground.
Copyright © 2000–2009, Texas Instruments Incorporated Submit Documentation Feedback 3