Datasheet
www.ti.com
BURST
I
PFM(LEAVE)
LOADCURRENT
V(OUT)
I
PFM(LEAVE)
I
PFM(ENTER)
INDUCTORCURRENT
TPS65810
TPS65811
SLVS658B – MARCH 2006 – REVISED FEBRUARY 2007
Figure 45. Typical Burst Operation in PFM Mode
The PFM operation is disabled and PWM operation set if one of the following events happen during PFM
operation:
1. The total burst operation time exceeds 10 µ s, typ.
2. The output voltage falls below 2% of the target regulation voltage.
The PFM mode can be disabled through the serial interface to force the individual converters to stay in fixed
frequency PWM mode.
64 Submit Documentation Feedback Copyright © 2006 – 2007, Texas Instruments Incorporated
Product Folder Link(s): TPS65810 TPS65811