Datasheet
www.ti.com
Batteryvoltage,
V(BAT)
Charge
Complete
Status,
Charger
Off
Pre-
conditioning
Phase
Current
Regulation
Phase
VoltageRegulationand
ChargeTermination
Phase
PRE-CHARGE
CURRENT AND
TERMINATION
THRESHOLD
BatteryCurrent,
I(BAT)
V
O(BATREG)
V
(LOWV)
T
(PRECHG)
T
(CHG)
FAST-CHARGE
CURRENT
I
O(BAT)
I
O(PRECHG) ,
I
(TERM)
DONE
DONE
BAT
ISET 1
I /K
(OUT) (SET)
OUT
ChargeVoltage
Loop
Battery
Switch
SystemVoltage
RegulationLoop
VREF
Thermal
Loop
VTJ
V
(OUT)
I
(BAT)
V
(BAT)
V
O(REG)
V
O(REG)
TPS65810
TPS65811
SLVS658B – MARCH 2006 – REVISED FEBRUARY 2007
Figure 34. Typical Charge Cycle, Thermal Loop not Active
If the operating conditions cause the IC junction temperature to exceed 125 ° C the charge cycle is modified, with
the activation of the integrated thermal control loop. The thermal control loop is activated when an internal
voltage reference, which is inversely proportional to the IC junction temperature, is lower than a fixed,
temperature stable internal voltage. The thermal loop overrides the other charger control loops and reduces the
charge current until the IC junction temperature returns to 125 ° C, effectively regulating the IC junction
temperature.
Copyright © 2006 – 2007, Texas Instruments Incorporated Submit Documentation Feedback 47
Product Folder Link(s): TPS65810 TPS65811