Datasheet

www.ti.com
POWER-UP PROCEDURE
5 POWER-UP PROCEDURE
1. Apply 4.5 V - 18 V to JP7.
2. Toggle JP1 to enable V
OUT
1.
3. Toggle JP6 and JP5 to enable switch 1 and Switch 2 respectively.
4. Apply loads to the output connectors.
6 SCHEMATIC AND BILL OF MATERIALS
Figure 7. TPS65280EVM Schematic
7
SLVU722June 2012 TPS65280EVM User’s Guide
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated