Datasheet
www.ti.com
Setup and Test Results
2 Setup and Test Results
This section explains the input, output, and jumper connections of the TPS65162EVM-278. It also
describes how to set up test equipment for evaluating the EVM and provides test results.
2.1 Connections and Jumpers
The DEFAULT jumper settings are required for the EVM to operate within the specifications of Table 1.
Table 2. Default Jumper Settings
Jumper Default Setting
J6 – Enable 1 (OFF) GND
J7 – Enable 2 (OFF) GND
J8 – Freq Control (750 khz) Vin
J9 – Enable Gate Voltage Shaping (ON) Vin
J10 – Control Gate Voltage
(ON) Vin
Shaping
J1-VIN/GND: Input power supply and ground connection, Vin range 8 V to 14 V
J2-Vs/GND: Output connection for the main boost converter and ground return connection
J3-VLOGIC/GND: Output voltage for 3.3-V buck converter and ground return connection
J4-VGH/GND: Output connection for the internal high-voltage switch and ground return connection
J5-VGL/GND: Output voltage for negative charge pump and ground return connection
J6–Enable 1: Enable for VLOGIC converter, GND = OFF, VIN = ON
J7–Enable 2: Enable for positive charge pump, GND = OFF, VIN=ON
J8–Freq Control: Frequency Selection, GND = 750 kHz, Vin = 500 kHz
J9–Enable Gate Gate Voltage Shaping, GND = OFF, VIN = ON
Voltage Shaping:
J10–Control Gate Control Voltage Shaping, GND = OFF, VIN = ON
Voltage Shaping:
J11-OPAMP 1: Opamp 1 input, output, gnd, and VS connection
J12-OPAMP 2: Opamp 2 input, output, gnd, and VS connection
J13-NEG1: Opamp 1 connection negative input and output
J14-NEG2: Opamp 2 connection negative input and output
J15- VGL reference voltage and ground return
GND/REFERENCE
:
J16-VS test point: Test point for VS
J17-VGH test point: Test point for VGH
J18-VGL test point: Test point for VGL
J19-VLOGIC test Test point for VLOGIC
point:
2.2 Recommended Test Setup
Before turning on the power supply, ensure that jumpers J6--J10 are in their default positions.
Connect a power supply rated at 3 A or more to provide 8 V to 14 V to J1. Do not exceed 14 V on J1. In
order to avoid voltage drop through the input power supply line, connect heavy-gauge, twisted-pair wire to
J1. The output voltages can be monitored by voltmeters and/or an oscilloscope with standard
high-impedance voltage probes.
3
SLVU228A–October 2007–Revised October 2009 TPS65162EVM-278
Submit Documentation Feedback
Copyright © 2007–2009, Texas Instruments Incorporated