Datasheet

Test Results
2-4
2.3 Test Results
Below are the efficiency results using this EVM:
Figure 2−1. TPS65100 VOUT1 Efficiency Using the CDRH5D28−4R2 Inductor
60
65
70
75
80
85
90
0.05 0.15 0.25 0.35 0.45
Io − Output Current − A
Efficiency − %
VIN = 5 V,
VOUT1 = 13.5 V
VIN = 3.3 V,
VOUT1 = 10 V
Note: Choosing a different inductor could change the effieciency by ± 5%.