Datasheet

2.1.10 J10–EN_DCDC1
2.1.11 J11–PWM/PFM MODE
2.1.12 J12–VDCDC1 and GND
2.1.13 J13–VDCDC2 and GND
2.1.14 J14–VDCDC3 and GND
2.1.15 J15–VLDO1 and GND
2.1.16 J16–VLDO2 and GND
2.1.17 J17–VDD_ALIVE and GND
2.1.18 J18– PWRFAIL
2.1.19 J19–EN_VDD_ALIVE
2.2 Setup
www.ti.com
Setup
Enable for the DCDC1 converter.
PWM or PFM Mode jumper, default setting is PWM.
The output from the DCDC1 switching regulator with a max output current of 1.0A and a default voltage
setting of 2.7V.
The output from the DCDC2 switching regulator with a max output current of 0.8A and a default voltage
setting of 1.8V.
The output from the DCDC3 switching regulator with a max output current of 0.8A and a default voltage
setting of 1.3V.
The output from the low drop out regulator, VLDO1, which has a max output current of 200mA and a
default voltage setting of 1.8V.
The output from the low drop out regulator, VLDO2, which has a max output current of 200mA and a
default voltage setting of 1.8V.
The output from the VDD_ALIVE low drop out regulator with a max output current of 30mA and a default
voltage setting of 1.2V.
The PWRFAIL output will assert low when the PWRFAIL comparator indicates a low Vin
Enable for the VDD_ALIVE low dropout regulator.
The EVM comes from the factory with the following default settings on the jumpers.
Jumper Shunt Location
J4 Between V-LO and DEFDCDC2
J5 Between V-HI and DEFDCDC3
J8 Between EN_DCDC3 and ON
J11 Between PWM and MODE
J19 Between ON and EN_VDD_ALIVE