Datasheet

www.ti.com
TPS65013
SLVS517A AUGUST 2004 REVISED JANUARY 2005
PIN ASSIGNMENTS (continued)
Terminal Functions (continued)
TERMINAL
I/O DESCRIPTION
NAME NO.
CHARGER SECTION
Open-drain output. Active low when UVLO comparator indicates low VBAT condition or
PWRFAIL 34 O when shutdown is about to occur due to an overtemperature condition or when the battery
cover is removed (BATT_COVER has gone low).
Indicates a charge fault or termination, or if any of the regulator outputs are below the lower
INT 35 O
tolerance level, active low (open drain)
LOW_PWR 36 I Input signal indicating deep-sleep mode, VCORE is lowered to predefined value or disabled
DEFMAIN 12 I Input signal indicating default VMAIN voltage, 0 = 1.8 V, 1 = 3.3 V
DEFCORE 1 I Input signal indicating default VCORE voltage, 0 = 1.3 V, 1 = 1.6 V
SCLK 30 I Serial interface clock line
SDAT 29 I/O Serial interface data/address
IFLSB 28 I LSB of serial interface address used to distinguish two devices with the same address
GPIO1 26 I/O General-purpose open-drain input/output
GPIO2 25 I/O General-purpose open-drain input/output
GPIO3 18 I/O General-purpose open-drain input/output
GPIO4 17 I/O General-purpose open-drain input/output
11