Datasheet
TPS63010
TPS63011
TPS63012
SLVS653B –JUNE 2008–REVISED MAY 2012
www.ti.com
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during
storage or handling to prevent electrostatic damage to the MOS gates.
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
AVAILABLE OUTPUT VOLTAGE OPTIONS
(1)
OUTPUT
PACKAGE
OUTPUT VOLTAGE VOLTAGE
T
A
PACKAGE PART NUMBER
(2)
DC/DC at VSEL = 1 DC/DC at
MARKING
VSEL = 0
Adjustable Adjustable TPS63010 TPS63010YFF
- 40°C to 85°C 3.3 V 2.8 V TPS63011 20-Pin WCSP TPS63011YFF
3.4 V 2.9 V TPS63012 TPS63012YFF
(1) Contact the factory to check availability of other fixed output voltage versions.
(2) The YFF package is available taped and reeled. Add R suffix to device type (e.g., TPS63010YFFR) to order quantities of 3000 devices
per reel. Add T suffix to device type (e.g., TPS63010YFFT) to order quantities of 250 devices per reel.
ABSOLUTE MAXIMUM RATINGS
over operating free-air temperature range (unless otherwise noted)
(1)
TPS6301x UNITS
V
I
Input voltage range on VIN, VINA, VINA1, L1, L2, VOUT, PS, SYNC, VSEL, – 0.3 to 7 V
EN, FB
T
J
Operating junction temperature range – 40 to 150 °C
T
stg
Storage temperature range – 65 to 150
Human Body Model (HBM)
(2)
2.5 kV
ESD Voltage Machine Model (MM)
(2)
150 V
Charged Device Model (CDM)
(2)
1 kV
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) ESD testing is performed according to the respective JESD22 JEDEC standard.
DISSIPATION RATINGS TABLE
THERMAL RESISTANCE POWER RATING DERATING FACTOR ABOVE
PACKAGE
(1)
Θ
JA
T
A
≤ 25°C T
A
= 25°C
YFF 84 °C/W 1190 mW 12 mW/°C
(1) For the most current package and ordering information, see the Package Option Addendum at the end of this document, or see the TI
website at www.ti.com.
RECOMMENDED OPERATING CONDITIONS
MIN NOM MAX UNIT
Supply voltage at VIN, VINA 2 5.5 V
Operating free air temperature range, T
A
– 40 85 °C
Operating junction temperature range, T
J
– 40 125 °C
2 Submit Documentation Feedback Copyright © 2008–2012, Texas Instruments Incorporated
Product Folder Link(s): TPS63010 TPS63011 TPS63012