Datasheet
SGLS243A − APRIL 2004 − REVISED JUNE 2008
9
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature range, V
I
= 3.6 V,
V
O
= 2.5 V, I
O
= 300 mA, EN = V
IN
, ILIM = V
IN
, T
J
= −40°C to 125°C (unless otherwise noted) (continued)
output
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
O
Adjustable output voltage range TPS62000 0.8 5.5 V
V
ref
Reference voltage TPS6200x 0.45 V
TPS62000
adjustable
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62000
adjustable
10 mA < I
O
≤ 600 mA −4% 3%
TPS62001
0.9 V
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62001
0.9 V
10 mA < I
O
≤ 600 mA −4% 3%
TPS62002
1 V
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62002
1 V
10 mA < I
O
≤ 600 mA −4% 3%
TPS62003
1.2 V
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62003
1.2 V
10 mA < I
O
≤ 600 mA −4% 3%
V
O
Fixed output voltage (see Note 4)
TPS62004
1.5 V
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
V
V
O
Fixed output voltage (see Note 4)
TPS62004
1.5 V
10 mA < I
O
≤ 600 mA −4% 3%
V
TPS62005
1.8 V
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62005
1.8 V
10 mA < I
O
≤ 600 mA −4% 3%
TPS62008
1.9 V
V
I
= 2.5 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62008
1.9 V
10 mA < I
O
≤ 600 mA −4% 3%
TPS62006
2.5 V
V
I
= 2.7 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62006
2.5 V
10 mA < I
O
≤ 600 mA −4% 3%
TPS62007
3.3 V
V
I
= 3.6 V to 5.5 V; 0 mA ≤ I
O
≤ 600 mA −4% 4%
TPS62007
3.3 V
10 mA < I
O
≤ 600 mA −4% 3%
Line regulation
V
I
= V
O
+ 0.5 V (min. 2 V) to 5.5 V,
I
O
= 10 mA
0.05 %/V
Load regulation V
I
= 5.5 V; I
O
= 10 mA to 600 mA 0.6%
Efficiency
V
I
= 5 V; V
O
= 3.3 V; I
O
= 300 mA
95%
η Efficiency
V
I
= 3.6 V; V
O
= 2.5 V; I
O
= 200 mA
95%
Start-up time I
O
= 0 mA, time from active EN to V
O
0.4 2 ms
NOTE 4: The output voltage accuracy includes line and load regulation over the full temperature range, T
J
= −40°C to 125°C.