Datasheet

www.ti.com
PIN ASSIGNMENTS
RSA Package
(Top View)
LBOVOUT
VOUT
EN
SYNC
LBI
NC
SW
SW
VOUT
FB
GND
PGND
VBAT
PGND
PGND
TPS61090
TPS61091, TPS61092
SLVS484A JUNE 2003 REVISED APRIL 2004
Electrical Characteristics (continued)
over recommended free-air temperature range and over recommended input voltage range (typical values are at an ambient
temperature range of 25°C) (unless otherwise noted)
DC/DC STAGE
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
Load regulation 0.6%
into
I
O
= 0 mA, V
EN
= VBAT = 1.8 V, VOUT =5 V 10 25 µA
VBAT
Quiescent current
into
I
O
= 0 mA, V
EN
= VBAT = 1.8 V, VOUT = 5 V 10 20 µA
VOUT
Shutdown current V
EN
= 0 V, VBAT = 2.4 V 0.1 1 µA
CONTROL STAGE
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
UVLO
Under voltage lockout threshold V
LBI
voltage decreasing 1.5 V
V
IL
LBI voltage threshold V
LBI
voltage decreasing 490 500 510 mV
LBI input hysteresis 10 mV
LBI input current EN = VBAT or GND 0.01 0.1 µA
LBO output low voltage V
O
= 3.3 V, I
OI
= 100 µA 0.04 0.4 V
LBO output low current 100 µA
LBO output leakage current V
LBO
= 7 V 0.01 0.1 µA
V
IL
EN, SYNC input low voltage 0.2 × VBAT V
V
IH
EN, SYNC input high voltage 0.8 × VBAT V
EN, SYNC input current Clamped on GND or VBAT 0.01 0.1 µA
Overtemperature protection 140 °C
Overtemperature hysteresis 20 °C
Terminal Functions
TERMINAL
I/O DESCRIPTION
NAME NO.
EN 11 I Enable input. (1/VBAT enabled, 0/GND disabled)
FB 14 I Voltage feedback of adjustable versions
3