Setup and Test Results
Table 2. Recommended Compensation Network Values at High/Low Frequency
FREQUENCY L ( µ H) V
S
(V) V
IN
± 20% (V) R
COMP
(k ) C
COMP
5 100 820 pF
15
3.3 91 1.2 nF
5 68 820 pF
High (1.2 MHz) 3.3 12
3.3 68 1.2 nF
5 39 820 pF
9
3.3 39 1.2 nF
5 51 1.5 nF
15
3.3 47 2.7 nF
5 33 1.5 nF
Low (650 kHz) 6.8 12
3.3 33 2.7 nF
5 18 1.5 nF
9
3.3 18 2.7 nF
Table 2 gives conservatives Rcomp and Comp values for certain inductors, input and output voltages
providing a very stable system. For a faster response time, a higher Rcomp value can be used to enlarge
the bandwidth, as well as a slightly lower value of Ccomp to keep enough phase margin. These
adjustments should be performed in parallel with the load transient response monitoring of TPS61087.
SLVU230A August 2008 Revised January 2009 TPS61087EVM 3
Submit Documentation Feedback