Datasheet

www.ti.com
REGISTER DESCRIPTION
REGISTER0 (READ/WRITE) (TPS6105X)
7 6 5 4 3 2 1 0
Memorylocation:00
Resetstate:00010010
000:0mA
(dc/dcswitching,LEDOff,VOUT setaccordingtoOV[1:0]
001:50mA
010:75mA (default)
011:100mA
100:150mA
101:200mA
110:250mA /400mA
TORCHCURRENT,TC[2:0]
(1)
111:250mA /500mA
ThisbitisonlyvalidforMODE_CTRL[1:0]=01
0:LEDcurrentisunchanged(default)
1:LEDcurrentisPWMdimmed(seeDCTIMbits)
ThisbitisonlyvalidforMODE_CTRL[1:0]=11
00:4.5Vconstantoutputvoltage
01:5.0Vconstantoutputvoltage
10:5.25Vconstantoutputvoltage
11:5.0Vconstantoutputvoltage
LEDDIMMING,DIM
OUTPUTVOLTAGE,OV[1:0]
(1)
(2)
(2)
(2)
(3)
(default)
00:Deviceinshutdownmode(default)
01:Deviceoperatesintorchonlymode
10:Deviceoperatesintorchandflashmodes
11:Deviceoperatesasconstantvoltagesource
WritingtoREGISTERS[7:6]automaticallyupdates
REGISTER[7:6].
MODECONTROL,MODE_CTRL[1:0]
MSB
LSB
TPS61050
TPS61052
SLUS525 MARCH 2007
(1) 400 mA/500 mA current level can only be activated when DIR = 0, Tx-MASK = 1 and GPIO input is set high. This
operating mode only applies to TPS61050.
(2) MODE_CTRL[1:0] = 00, VOUT is one body diode below the input voltage, I
Q
= 0.3 µ A (typ).
(3) MODE_CTRL[1:0] = 00, rectifier MOSFET is turned on shorting VOUT and SW, I
Q
= 150 µ A (typ).
26
Submit Documentation Feedback