Datasheet

www.ti.com
ELECTRICAL CHARACTERISTICS
TPS61010, TPS61011
TPS61012, TPS61013
TPS61014, TPS61015, TPS61016
SLVS314D SEPTEMBER 2000 REVISED JUNE 2005
over recommended operating free-air temperature range, VBAT = 1.2 V, EN = VBAT (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
R
L
= 33 0.85 0.9
Minimum input voltage for
start-up
V
I
R
L
= 3 k , T
A
= 25 ° C 0.8 V
Input voltage once started I
O
= 100 mA 0.8
Programmable output
TPS61010, I
OUT
= 100 mA 1.5 3.3 V
voltage range
TPS61011, 0.8 V < V
I
< V
O
, I
O
= 0 to 100 mA 1.45 1.5 1.55
V
TPS61012, 0.8 V < V
I
< V
O
, I
O
= 0 to 100 mA 1.74 1.8 1.86
TPS61013, 0.8 V < V
I
< V
O
, I
O
= 0 to 100 mA 2.42 2.5 2.58 V
TPS61013, 1.6 V < V
I
< V
O
, I
O
= 0 to 200 mA 2.42 2.5 2.58 V
V
O
TPS61014, 0.8 V < V
I
< V
O
, I
O
= 0 to 100 mA 2.72 2.8 2.88 V
Output voltage
TPS61014, 1.6 V < V
I
< V
O
, I
O
= 0 to 200 mA 2.72 2.8 2.88 V
TPS61015, 0.8 V < V
I
< V
O
, I
O
= 0 to 100 mA 2.9 3.0 3.1 V
TPS61015, 1.6 V < V
I
< V
O
, I
O
= 0 to 200 mA 2.9 3.0 3.1 V
TPS61016, 0.8 V < V
I
< V
O
, I
O
= 0 to 100 mA 3.2 3.3 3.4 V
TPS61016, 1.6 V < V
I
< V
O
, I
O
= 0 to 200 mA 3.2 3.3 3.4 V
V
I
> 0.8 V 100
Maximum continuous output
I
O
mA
current
V
I
> 1.8 V 250
TPS61011, once started 0.39 0.48
TPS61012, once started 0.54 0.56
TPS61013, once started 0.85 0.93
I
(SW)
Switch current limit A
TPS61014, once started 0.95 1.01
TPS61015, once started 1 1.06
TPS61016, once started 1.07 1.13
V
(FB)
Feedback voltage 480 500 520 mV
f Oscillator frequency 420 500 780 kHz
D Maximum duty cycle 85%
NMOS switch on-resistance 0.37 0.51
r
DS(on)
V
O
= 1.5 V
PMOS switch on-resistance 0.45 0.54
NMOS switch on-resistance 0.2 0.37
r
DS(on)
V
O
= 3.3 V
PMOS switch on-resistance 0.3 0.45
Line regulation
(1)
V
I
= 1.2 V to 1.4 V, I
O
= 100 mA 0.3
%/V
Load regulation
(1)
V
I
= 1.2 V; I
O
= 50 mA to 100 mA 0.1
Autodischarge switch
300 400
resistance
Residual output voltage
ADEN = VBAT; EN = GND 0.4 V
after autodischarge
V
IL
LBI voltage threshold
(2)
V
(LBI)
voltage decreasing 480 500 520 mV
LBI input hysteresis 10 mv
LBI input current 0.01 0.03
V
OL
LBO output low voltage V
(LBI)
= 0 V, V
O
= 3.3 V, I
(OL)
= 10 µA 0.04 0.2 V
LBO output leakage current V
(LBI)
= 650 mV, V
(LBO)
= V
O
0.03 µA
FB input bias current
I
(FB)
V
(FB)
= 500 mV 0.01 0.03
(TPS61010 only)
EN and ADEN input low
V
IL
0.8 V < V
BAT
< 3.3 V 0.2 × VBAT V
voltage
(1) Line and load regulation is measured as a percentage deviation from the nominal value (i.e., as percentage deviation from the nominal
output voltage). For line regulation, x %/V stands for ± x% change of the nominal output voltage per 1-V change on the input/supply
voltage. For load regulation, y% stands for ± y% change of the nominal output voltage per the specified current change.
(2) For proper operation the voltage at LBI may not exceed the voltage at V
BAT
.
3