Datasheet
TPS60200, TPS60201, TPS60202, TPS60203
REGULATED 3.3 V, 100-mA LOW-RIPPLE CHARGE PUMP
LOW POWER DC/DC CONVERTERS
SLVS274 – MARCH 2000
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
detailed description (continued)
Table 1. Recommended Values for the Resistive Divider From the E96 Series (±1%)
V
(IN)
/V R1/kΩ R2/kΩ V
TRIP(MIN)
/V V
TRIP(MAX)
/V
1.6 267 750 1.524 1.677
1.7 301 681 1.620 1.785
1.8 340 649 1.710 1.887
1.9 374 619 1.799 1.988
2.0 402 576 1.903 2.106
power-good detector (TPS60201 and TPS60203)
The power-good output is an open-drain output that pulls low when the output is out of regulation. When the
output rises to within 90% of its nominal voltage, the power-good output is released. Power-good is high
impedance in shutdown. In normal operation, an external pullup resistor must be connected between PG and
OUT, or any other voltage rail in the appropriate range. The resistor should be in the 100-kΩ to 1-MΩ range.
If the PG output is not used, it should remain unconnected.
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Voltage range: IN, OUT, EN, LBI, LBO, PG to GND –0.3 V to 3.6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C1+, C2+ to GND –0.3 V to (V
O
+ 0.3 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C1–, C2– to GND –0.3 V to (V
I
+ 0.3 V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See dissipation rating table. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current TPS60200, TPS60201 150 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous output current TPS60202, TPS60203 75 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–55°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
DISSIPATION RATING TABLE 1 FREE-AIR TEMPERATURE
PACKAGE
T
A
≤ 25°C
POWER RATING
DERATING FACTOR
ABOVE T
A
= 25°C
T
A
= 70°C
POWER RATING
T
A
= 85°C
POWER RATING
DGS 424 mW 3.4 mW/ C 187 mW 136 mW
The thermal resistance junction to ambient of the DGS package is R
TH–JA
= 294°C/W.
recommended operating conditions
MIN NOM MAX UNIT
Input voltage range, V
I
1.6 3.6 V
Input capacitor, C
i
2.2 µF
Flying capacitors, C1, C2 1 µF
Output capacitor, C
o
2.2 µF
Operating junction temperature, T
J
–40 125 °C