Datasheet


   
   
SLVS215C − JUNE 1999 − REVISED AUGUST 2008
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
1
2
3
4
5
6
7
8
9
10
20
19
18
17
16
15
14
13
12
11
GND
SYNC
ENABLE
FB
OUT
C1+
IN
C1−
PGND
PGND
GND
CLK
COM
SKIP
OUT
C2+
IN
C2−
PGND
PGND
PWP PACKAGE
(TOP VIEW)
Figure 2. Bottom View of PWP Package,
Showing the Thermal Pad
Thermal
Pad
AVAILABLE OPTIONS
PACKAGE
TSSOP
(PWP)
TPS60110PWP
This package is available taped and reeled. To order this packaging
option, add an R suffix to the part number (e.g., TPS60110PWPR).
Terminal Functions
TERMINAL
I/O
DESCRIPTION
NAME NO.
I/O
DESCRIPTION
CLK 19 I Input for external clock signal. If the internal clock is used, connect this terminal to GND.
C1+ 6 Positive terminal of the charge-pump capacitor C
1F
C1− 8 Negative terminal of the charge-pump capacitor C
1F
C2+ 15 Positive terminal of the charge-pump capacitor C
2F
C2− 13 Negative terminal of the charge-pump capacitor C
2F
COM 18 I Mode selection.
When COM is logic low the charge pump operates in push-pull mode to minimize output ripple. When COM is
connected to IN the regulator operates in single-ended mode requiring only one flying capacitor.
ENABLE 3 I ENABLE Input. The device turns off, the output disconnects from the input, and the supply current decreases
to 0.05 µA when ENABLE is a logic low. ENABLE High may only be applied when VIN is inside the recommended
operating range.
FB 4 I FEEDBACK input. Connect FB to OUT as close to the load as possible to achieve best regulation. Resistive
divider is on-chip to match internal reference voltage of 1.22 V.
GND 1, 20 GROUND. Analog ground for internal reference and control circuitry. Connect to PGND through a short trace.
IN 7, 14 I Supply Input. Connect to an input supply in the 2.7-V to 5.4-V range. Bypass IN to GND with a (C
O
/2) µF
capacitor. Connect both INs through a short trace.
OUT 5, 16 O Regulated 5-V power output. Connect both OUTs through a short trace and bypass OUT to GND with the output
filter capacitor C
O
.
PGND 9−12 PGND power ground. Charge-pump current flows through this pin. Connect all PGNDs together.
SKIP 17 I Mode selection. When SKIP is logic low, the charge pump operates in constant-frequency mode. Output ripple
and noise are minimized in this mode. When SKIP is connect to IN, the device operates in pulse skip mode.
Quiescent current is lowest in this mode.
SYNC 2 I Selection for external clock signal. Connect to GND to use the internally generated clock signal. Connect to IN
for external synchronization. In this case, the clock signal needs to be fed through CLK.
PowerPAD Must be soldered to achieve appropriate power dissipation. Should be connected to PGND.