Datasheet
Test Setup
www.ti.com
5.1.7 Oscilloscope
A digital or analog oscilloscope can be used to measure the output ripple. The oscilloscope must be set
for 1-MΩ impedance, 20-MHz bandwidth, AC coupling, 2-µs/division horizontal resolution, 50-mV/division
vertical resolution. Test points TP27 and TP37 can be used to measure the output ripple voltage for CPU
and GPU. Do not use a leaded ground connection as this can induce additional noise due to the large
ground loop.
5.2 Recommended Wire Gage
1. V5in to J31 (5-V input):
The recommended wire size is 1 x AWG 18 per input connection, with the total length of wire less than
4 feet (2- foot input, 2-foot return).
2. 12VBAT to J30 (12-V input):
The recommended wire size is 1 x AWG 16 per input connection, with the total length of wire less than
4 feet (2-foot input, 2-foot return).
3. J1, J5, J6 (CPU) to LOAD or J11 (GPU) to LOAD or J28 (VDDQ) to LOAD or J24 (VCCIO) to
LOAD
The minimum recommended wire size is 2 x AWG 16, with the total length of wire less than 4 feet
(2-foot output, 2-foot return)
5.3 Recommended Test Setup
Figure 17 is the recommended test setup to evaluate the TPS59640EVM-751. Working at an ESD
workstation, ensure that any wrist straps, bootstraps, or mats are connected referencing the user to earth
ground before handling the EVM.
22
Using the TPS59640EVM-751 IMVP-7, 3-Phase CPU/1-Phase GPU SVID SLUU796–January 2012
Power System
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated