Datasheet
50
200
250
300
350
400
100
0 0.2 0.4 0.6 0.8 1.0 1.4
T
A
= 0°C
I
L
- Load Current - A
t
ON
- Minimum Controllable Pulse Width - ns
–40
0
25
85
T
A
(°C)
T
A
= –40°C
T
A
= 25°C
T
A
= 85°C
1.2
150
-50 -25 0 25 50 75 100 125
T
J
- Junction Temperature - °C
I
SW(off)
- Switching Node Leakage Current - mA
2
3
1
4
5
4 8 12 16 20 24 28
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
5.0
OCL = 4.5 A
OCL = 3.0 A
OCL = 1.5 A
V
DD
- Supply Voltage - V
I
OC
- Overcurrent Limit - A
TPS55383 , , TPS55386
www.ti.com
......................................................................................................................................................................................... SLUS818 – SEPTEMBER 2008
TYPICAL CHARACTERISTICS (continued)
SWITCHING NODE LEAKAGE CURRENT MINUMUM CONTROLLABLE PULSE WIDTH
vs vs
JUNCTION TEMPERATURE LOAD CURRENT
Figure 13. Figure 14.
OVERCURRENT LIMIT
vs
SUPPLY VOLTAGE
Figure 15.
Copyright © 2008, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Link(s): TPS55383 TPS55386