Datasheet

C4: V
OUT
AC Coupled (200 mV/div)
C3: I
OUT
(500 mA/div)
Timebase = 500 µs/div
C4: V
OUT
AC Coupled (200 mV/div)
C3: I
OUT
(500 mA/div)
Timebase = 500 µs/div
Test Setup and Results
www.ti.com
4.5 Load Transients
Figure 4 and Figure 5 show the TPS55340EVM-147 response to load transients. The current step is from
25% to 75% of maximum rated load at a 6V input and a 18V input respectively. The current step slew rate
is 10 mA/µs. Total peak-to-peak voltage variation is as shown, including ripple and noise on the output.
Figure 4. TPS55340EVM-147 V
IN
= 6V Transient Response
Figure 5. TPS55340EVM-147 V
IN
= 18V Transient Response
6
TPS55340EVM-147, 6V to 18V Input, 12V Output SEPIC Evaluation Module SLVU742AJune 2012Revised August 2013
Submit Documentation Feedback
Copyright © 2012–2013, Texas Instruments Incorporated