Datasheet

V
OUT
AC Coupled (500 mV/div)
I
OUT
(200 mA/div)
Timebase (1.00 ms/div)
V
OUT
AC Coupled (500 mV/div)
I
OUT
(200 mA/div)
Timebase (1.00 ms/div)
Test Setup and Results
www.ti.com
4.5 Load Transients
Figure 4 and Figure 5 show the EVM's response to load transients. The current step is from 25% to 75%
of maximum rated load at a 5-V input and a 12-V input respectively. The current step slew rate is 10
mA/µs. Total peak-to-peak voltage variation is as shown, including ripple and noise on the output.
Figure 4. TPS55340EVM-017 V
IN
= 5-V Transient Response
Figure 5. TPS55340EVM-017 V
IN
= 12-V Transient Response
6
TPS55340EVM-017, 5-V to 12-V Input, 24-V Output Boost Evaluation Module SLVU668AApril 2012Revised July 2012
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated