Datasheet
Load Transients
2-6
2.5 Load Transients
The TPS54x72EVM−222 response to load transients is shown in Figure 2−6,
Figure 2−7, and Figure 2−8. The current step is from 25 to 75 percent of
maximum rated load. Total peak-to-peak voltage variation is as shown,
including ripple and noise on the output.
Figure 2−6. Load Transient Response, TPS54672
V
O
(ac) 50 mV/div
I
O
2 A/div
Time Scale 250 µs/div
Figure 2−7. Load Transient Response, TPS54872
V
O
(ac) 50 mV/div
I
O
2 A/div
Time Scale 250 µs/div