Modifying the value of C6 can change the slow start time of the SLVP213. Use
the following equation to calculate the required value of C6 for a specific slow
start time. With C6 left open, the slow start time is typically 3.6 ms. The slow
start time cannot be made faster than 3.6 ms.
R6 +
T
SS
5 mA
0.891 V