Datasheet

Loop Characteristics
2-9
Test Setup and Results
2.6 Loop Characteristics
The TPS54x73EVM-225 load response characteristics are shown in
Figure 29, Figure 210, and Figure 211. The current step is from 50% to
50% of maximum rated load. Total peak-to-peak voltage variation is as shown,
including ripple and noise on the output.
Figure 29. Measured Loop Response, TPS54673, V
I
= 3 V
60
50
40
30
20
10
0
10
20
30
40
50
60
100 1 k 10 k 100 k 1 M
180
150
120
90
60
30
0
30
60
90
120
150
180
Gain
Phase
Gain dB
f Frequency Hz
MEASURED LOOP RESPONSE
Phase Degrees
Figure 210. Measured Loop Response, TPS54673, V
I
= 6 V
60
50
40
30
20
10
0
10
20
30
40
50
60
100 1 k 10 k 100 k 1 M
180
150
120
90
60
30
0
30
60
90
120
150
180
Gain
Phase
Gain dB
f Frequency Hz
MEASURED LOOP RESPONSE
Phase Degrees