2.1 Input/Output Connections
The TPS54610 EVM has the following input/output connections: J1 (V
in
and
GND) and J3 (V
out
and GND). A diagram showing the connection points is
shown in Figure 21. Connect a power supply capable of supplying 6 A to J1
through a pair of 20 AWG wires. Connect the load to J3 through a pair of 16
AWG wires. Minimize wire lengths to reduce losses in the wires. Test point TP5
provides easy connection for an oscilloscope voltage probe to monitor the
output voltage.
Figure 21. Connection Diagram