Datasheet

±0.3
±0.2
±0.1
0.0
0.1
0.2
0.3
5 10 15 20 25 30 35 40 45 50 55 60
Output Voltage Normalized (%)
V
I
- Input Voltage (V)
C024
±0.6
±0.5
±0.4
±0.3
±0.2
±0.1
±0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
Output Voltage Normalized (%)
I
O
- Output Current (A)
C024
TPS54560
www.ti.com
SLVSBN0A MARCH 2013REVISED MARCH 2014
V
IN
= 12 V V
OUT
= 5 V ƒsw = 400 kHz
V
OUT
= 5 V I
OUT
= 5 A ƒsw = 400 kHz
Figure 56. Regulation vs Load Current
Figure 57. Regulation vs Input Voltage
10 Power Supply Recommendation
The devices are designed to operate from an input voltage supply range between 4.5 V and 60 V. This input
supply should be well regulated. If the input supply is located more than a few inches from the TPS54560
converter additional bulk capacitance may be required in addition to the ceramic bypass capacitors. An
electrolytic capacitor with a value of 100 μF is a typical choice.
Copyright © 2013–2014, Texas Instruments Incorporated Submit Documentation Feedback 35