Datasheet
TPS54528
SLVSAY4C –JULY 2011–REVISED MARCH 2014
www.ti.com
7 Specifications
7.1 Absolute Maximum Ratings
over operating free-air temperature range (unless otherwise noted)
(1)
VALUE
UNIT
MIN MAX
VIN, EN –0.3 20
VBST –0.3 26
VBST (10 ns transient) –0.3 28
Input voltage range VBST (vs SW) –0.3 6.5 V
VFB, SS –0.3 6.5
SW –2 20
SW (10 ns transient) –3 22
VREG5 –0.3 6.5
Output voltage range V
GND –0.3 0.3
Voltage from GND to thermal pad, V
diff
–0.2 0.2 V
Operating junction temperature, T
J
–40 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended
Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
7.2 Handling Ratings
MIN MAX UNIT
T
stg
Storage temperature range –55 150 °C
Human Body Model (HBM) 2 kV
Electrostatic discharge
Charged Device Model (CDM) 500 V
7.3 Recommended Operating Conditions
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
IN
Supply input voltage 4.5 18 V
VBST –0.1 24
VBST (10 ns transient) –0.1 27
VBST(vs SW) –0.1 5.7
SS –0.1 5.7
V
I
Input voltage EN –0.1 18 V
VFB –0.1 5.5
SW –1.8 18
SW (10 ns transient) –3 21
GND –0.1 0.1
V
O
Output voltage VREG5 –0.1 5.7 V
I
O
Output Current I
VREG5
0 5 mA
T
A
Operating free-air temperature –40 85 °C
T
J
Operating junction temperature –40 150 °C
4 Copyright © 2011–2014, Texas Instruments Incorporated
Product Folder Links: TPS54528