Datasheet

°
2.31
7
1
2.46
14
8
Thermal Pad
TPS54525
www.ti.com
SLVSB82A MAY 2012REVISED JULY 2013
VREG5 Capacitor Selection
A 1.0 µF ceramic capacitor must be connected between the VREG5 to GND pin for proper operation. It is
recommended to use a ceramic capacitor.
THERMAL INFORMATION
This PowerPad™ package incorporates an exposed thermal pad that is designed to be directly to an external
heartsick. The thermal pad must be soldered directly to the printed board (PCB). After soldering, the PCB can be
used as a heartsick. In addition, through the use of thermal vias, the thermal pad can be attached directly to the
appropriate copper plane shown in the electrical schematic for the device, or alternatively, can be attached to a
special heartsick structure designed into the PCB. This design optimizes the heat transfer from the integrated
circuit (IC).
For additional information on the PowerPAD™ package and how to use the advantage of its heat dissipating
abilities, refer to Technical Brief, PowerPAD™ Thermally Enhanced Package, Texas Instruments Literature No.
SLMA002 and Application Brief, PowerPAD™ Made Easy, Texas Instruments Literature No. SLMA004.
The exposed thermal pad dimensions for this package are shown in the following illustration.
Figure 15. Thermal Pad Dimensions
Copyright © 2012–2013, Texas Instruments Incorporated 15
Product Folder Links :TPS54525