Datasheet

Output Voltage Regulation
2-5
Test Setup and Results
2.4 Output Voltage Regulation
The output voltage load regulation of the SLVP215 is shown in Figure 24,
while the output voltage line regulation is shown in Figure 25. Measurements
are given for an ambient temperature of 25°C.
1.245
1.247
1.249
1.251
1.253
1.255
01 234
Output Voltage V
OUTPUT VOLTAGE
vs
OUTPUT CURRENT
I
O
Output Current A
V
O
1.247
1.248
1.249
1.25
1.251
1.252
1.253
34 56
V
I
Input Voltage V
I
O
= 0 A
I
O
= 1.5 A
I
O
= 3 A
Output Voltage V
OUTPUT VOLTAGE
vs
INPUT VOLTAGE
V
O
Figure 24. Load Regulation
Figure 25. Line Regulation
2.5 Load Transients
The SLVP215 response to load transients is shown in Figure 26 and
Figure 27. The current step in Figure 26 is 0 to 2.25 A, while the current step
in Figure 27 is 1.5 A to 1.5 A (sinking to sourcing). Total peak-to-peak
voltage variation is as shown, including ripple and noise on the output.
(AC) 50 mV/div
1 A/div
V
O
I
O
Time Scale 25 µs/div
(AC) 50 mV/div
1 A/div
V
O
I
O
Time Scale 100 µs/div
Figure 26. Source-Sink Current
Transient Response
Figure 27. Load Transient Response