Datasheet
Time = 2 s/divm
1 A/div
10 V/div
20 mV/div
C3: V ac coupled
IN
C1: SW
C4: I
L
I = 3.5 A
OUT
C3
C4
C1
Time = 2 s/divm
500 mA/div
10 V/div
20 mV/div
C3: V ac coupled
IN
C1: SW
C4: I
L
I = 100 mA
OUT
C3
C4
C1
www.ti.com
Test Setup and Results
2.7 Input Voltage Ripple
The EVM CCM input voltage ripple is shown in Figure 13. The output current is the rated full load of 3.5 A
and V
IN
= 12 V. The voltage ripple is measured directly across the input capacitors.
The DCM input voltage ripple is shown in Figure 14. The output current is 0.1 A and V
IN
= 12 V.
Figure 13. Input Voltage Ripple CCM Figure 14. Input Voltage Ripple DCM
9
SLVU769B–September 2012–Revised September 2012 Using the TPS54360 Step-Down Converter Evaluation Module
Submit Documentation Feedback