Datasheet
−0.4
−0.3
−0.2
−0.1
0
0.1
0.2
0.3
0.4
4 8 12 16 20
Input Voltage (V)
Output Voltage Deviation (%)
I
OUT
= 1.5 A
G003
V = 100 mV / div (dc coupled, -850 mV offset)
OUT
I = 1 A / DIV
OUT
Time = 50 µsec / div
Load step = 1 A to 2 A
Slew rate = 1 A / µsec
www.ti.com
Test Setup and Results
Figure 4. TPS54329EEVM-056 Line Regulation
4.6 Load Transient Response
The TPS54329EEVM-056 response to load transient is shown in Figure 5. The current step is from 1 A to
2 A. Total peak-to-peak voltage variation is as shown.
Figure 5. TPS54329EEVM-056 Load Transient Response, 1-A to 2-A Step
The TPS54329EEVM-056 response to load transient during Eco-mode™ operation is shown in Figure 6.
The initial load current is 0.01 A, and the TPS54329E is operating in Eco-mode™. The load step is to 1 A,
taking the TPS54329E out of Eco-mode™ operation as shown in the V
OUT
waveform.
7
SLVU487– October 2011 TPS54329EEVM-056, 3-A, SWIFT™ Regulator Evaluation Module
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated