Datasheet
Output Voltage Regulation
2-5
Test Setup and Results
2.5 Output Voltage Regulation
The output voltage load regulation, with a 5-V input and a 25
°
C ambient
temperature, is shown in Figure 2–5. Over the load range of 0 A to 3 A, the
output voltage varies less than 0.2%.
Figure 2–5. Measured Load Regulation
0.99
0.992
0.994
0.996
0.998
1
1.002
1.004
1.006
1.008
1.01
0 0.5 1 1.5 2 2.5 3
I
L
– Load Current – A
T
A
= 25°C
V
I
= 5 V
(Normalized to 1.5 A Load)
– Output Voltage – V
V
O