Datasheet

Input/Output Connections
2-2
2.1 Input/Output Connections
The TPS54310 EVM has the following four input/output connections: J1 (V
in
and GND) and J3 (V
out
and GND). A diagram showing the connection points
is shown in Figure 21. Connect a power supply capable of supplying 3 A to
J1 through a pair of 20 AWG wires. Connect the load to J3 through a pair of
20 AWG wires. Minimize wire lengths to reduce losses in the wires. Test point
TP8 provides easy connection for an oscilloscope voltage probe to monitor the
output voltage.
Figure 21. Connection Diagram