Datasheet

TPS54262-Q1
www.ti.com
SLVS996C SEPTEMBER 2009REVISED JUNE 2010
TYPICAL CHARACTERISTICS (continued)
Output Voltage Drop Out
V
Reg
DROP OUT OUTPUT VOLTAGE TRACKING
Figure 9. Figure 10.
NOTE
Power up (Start up): This curve shows the input voltage required to achieve the 5 V regulation
during power up over the range of load currents (see Figure 10).
Power down (Tracking): This curve shows the input voltage at which the output voltage drops
approximately by 0.7 V from the programmed 5 V regulated voltage (see Figure 10) or for low
input voltages (tracking function) over the range of load currents (see Figure 9).
In Figure 5 and Figure 6, L and C are output inductor and capacitor respectively.
Copyright © 2009–2010, Texas Instruments Incorporated Submit Documentation Feedback 9
Product Folder Link(s): TPS54262-Q1