Datasheet
Vout=2V/div
PH=10V/div
InductorCurrent=500mA /div
Time=2usec/div
Vout=2V/div
PH=10V/div
InductorCurrent=500mA /div
Time=2usec/div
www.ti.com
Test Setup and Results
2.10 Continuous Conduction Mode Operation
When the output current is greater than one half the peak to peak inductor current, the circuit is operating
in continuous conduction mode (CCM). The output voltage, PH node voltage and inductor current for CCM
is shown in Figure 10.
Figure 10. Continuous Conduction Mode Operation
2.11 Discontinuous Conduction Mode Operation
When the output current is less than one half the peak to peak inductor current, the circuit is operating in
discontinuous conduction mode (DCM). The circuit enters DCM when the nominal output current falls
below 0.337 A. The output voltage, PH node voltage and inductor current for DCM is shown in Figure 11
Figure 11. Discontinuous Conduction Mode Operation
9
SLVU372–March 2009 TPS54260EVM-597 2.5-A, SWIFT™ Regulator Evaluation Module
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated