Datasheet
Input/Output Connections
2-2
2.1 Input/Output Connections
The TPS54010EVM-067 is provided with input/output connectors and test
points as shown in Table 2−1. Connect a power supply capable of supplying
12 A to J1 through a pair of 14 AWG wires. Connect a power supply capable
of supplying 25 mA to J2 through a pair of 22 AWG wires. Connect the load
to J3 through a pair of 14 AWG wires. The maximum load current capability
is 14 A. Minimize wire lengths to reduce losses in the wires. Test points TP1
and TP2 provide a place to monitor the the PVIN and VIN input voltages wth
TPS providing a convenient ground reference. Use TP7 to monitor the output
voltage with TP8 as the ground reference.
Table 2−1.EVM Connectors and Test Points
Reference
Designator
Function
J1 PVIN, 2.2 V to 3.5 V nominal
J2 VIN, 3.3 V nominal, 3 V to 4 V
J3 VOUT, 1.5 V at 14 A maximum
J4 3-pin header for VIN, SYNC and GND. With R4 open, jumper SYNC to VIN for 550−kHz
operation or SYNC to GND for 350−kHz operation,
J5 2-pin header for ENA, ground to disable , open to enable
JP1 Jumper to connect VIN to PVIN
TP1 VIN test point at VIN connector
TP2 PVIN test point at PVIN connector
TP3 GND test point at VIN and PVIN connectors
TP4 PWRGD signal monitor test point
TP5 Test point used for loop response measurements
TP6 PH test point
TP7 Output voltage test point at VOUT connector
TP8 GND test point at VOUT connector