5 Configurations
All jumper selections must be made prior to applying power to the EVM. Users can configure this EVM per
the following configurations.
5.1 Switching Frequency Selection
The switching frequency can be set by J5.
Default setting: 500 kHz
Table 2. Switching Frequency Selection
Resistor (RF) Connections
Jumper Set to Switching Frequency (kHz)
(kΩ)
Top (1–2 pin shorted) 0 250
Second (3–4 pin shorted) 187 300
Third (5–6 pin shorted) 619 400
Fourth (7–8 pin shorted) Open 500
Fifth (9–10 pin shorted) 866 650
Sixth (11–12 pin shorted) 309 750
Seventh (13–14 pin shorted) 124 850
Bottom (15–16 pin shorted) 0 970
5.2 Soft-Start Selection
The soft-start time can be set by J4.
Default setting: 1.4 ms
Table 3. Soft-Start Time Selection
Jumper Set to R
MODE
Connections (kΩ) Soft-Start Time (ms)
Top (1–2 pin shorted) 39.2 0.7
Second (3–4 pin shorted) 100 1.4
Third (5–6 pin shorted) 200 2.8
Bottom (7–8 pin shorted) 475 5.6
5.3 Mode Selection
The MODE can be set by J6.
Default setting: Auto Skip
Table 4. MODE Selection
Jumper Set to MODE Selection
Top (1–2 pin shorted) Auto Skip
Bottom (7–8 pin shorted) Forced CCM