Datasheet
www.ti.com
Test Procedure
Table 5. VID Bits Selection
(1)
(continued)
VID3 VID2 VID1 VID0 Vout(V)
1 1 0 1 0.925
1 1 1 1 0.875
5.5 Phase Control Selection (PCNT)
The phase control can be set by J10 (PCNT).
Default setting is jumper on pin1 and pin 2 of J10 for Auto phase control.
Table 6. Phase Control Selection
JUMPER SET TO PHASE CONTROL
1-2 pin shorted Auto phase control (around 12-A change to dual phase)
2-3 pin shorted Single phase
No Jumper Dual phase
5.6 1.5-V Output Voltage Selection (J1: 1.5-Vout Selection)
The 1.5-V output can be set by J1 (Vout Select).
Default setting: Jumper shorts on J1 to set 1.25-V output.
Table 7. 1.5-V Output Option Selection
JUMPER SET TO OUTPUT RANGE
No Jumper 1.5-V output
Jumper shorted 4-bits VID with 0.875 V – 1.25 V
6 Test Procedure
6.1 Line/Load Regulation and Efficiency Measurement Procedure
1. Ensure that Load is set to constant resistance mode and to sink 0 Adc.
2. Ensure that the jumper provided in the EVM is set to short on J11 before Vin is applied.
3. Increase Vin from 0 V to 12 V. Using V1 to measure input voltage.
4. Remove the jumper on J11 to enable the controller.
5. Vary Load from 0 Adc to 40 Adc; Vout must remain in load regulation.
6. Vary Vin from 8 V to 14 V; Vout must remain in line regulation.
7. Put the jumper on J11 to disable the controller.
8. Decrease Load to 0 A
9. Decrease Vin to 0 V.
6.2 List of Test Points
Table 8. Functions of Each Test Points
Test Points Name Description
TP1 PMON Power Monitor Output, SeeFigure 8.
TP2 PCNT Phase Control Input
TP3 SW1 Phase 1 Switching Node
TP4 SW2 Phase 2 Switching Node
9
SLUU379–November 2009 Using the TPS51727EVM, a Dual-Phase, Eco-mode™ Step-Down Power
Management IC for 40-A+ Application
Submit Documentation Feedback
Copyright © 2009, Texas Instruments Incorporated