5.1 Current Limit Trip Selection (J8: Trip Select)
The overcurrent protection (OCP) can be set by J8 Trip Select.
Default setting is 30 mV.
Table 2. Current Limit Trip Selection
Jumper Set To Trip Select OCP Limit per Phase (Typical)
Top (7-8 pin shorted) GND (15 mV) 15.1 A
Second (5-6 pin shorted) VREF (20 mV) 18.4 A
Third (3-4 pin shorted) 3.3VBIAS (25 mV) 22.3 A
Bottom (1-2 pin shorted) V5FILT(30 mV) 27.9 A
5.2 Frequency Selection (J7: TON Select)
The operating frequency can be set by J7 TON Select.
Default setting is 300 kHz.
Table 3. Frequency Selection
Jumper Set To TON Select Frequency (kHz)
Top (7-8 pin shorted) GND 200
Second (5-6 pin shorted) VREF 300
Third (3-4 pin shorted) 3.3VBIAS 400
Bottom (1-2 pin shorted) V5FILT 500
5.3 Overshoot Reduction Selection (J9: OSR Select)
The overshoot reduction can be set by J9 OSR™ Select.
Default setting is Minimum.
Table 4. Overshoot Reduction Selection
Jumper Set To OSR Overshoot Voltage
Top (7-8 pin shorted) GND (Minimum) Minimum
Second (5-6 pin shorted) VREF (Medium) Medium
Third (3-4 pin shorted) 3.3VBIAS (Maximum) Maximum
Bottom (1-2 pin shorted) V5FILT (Off) OSR Off
5.4 VID Bits Selection (S1)
The output voltage can be set by Switch S1(VID Bits).
Default setting is 0000.
Table 5. VID Bits Selection
(1)
VID3 VID2 VID1 VID0 Vout(V)
0 0 0 0 1.250
0 0 1 1 1.175
0 1 0 1 1.125
0 1 1 1 1.075
1 0 0 1 1.025
1 0 1 1 0.975
(1)
4-Bit VID Table (1=3.3VBIAS=on, 0=GND=off)
8
Using the TPS51727EVM, a Dual-Phase, Eco-mode™ Step-Down Power SLUU379November 2009
Management IC for 40-A+ Application