Datasheet

Configuration
www.ti.com
5.1 Current Limit Trip Selection (J8: Trip Select)
The overcurrent protection (OCP) can be set by J8 Trip Select (TRIPSEL).
Default setting is 29A.
Table 2. Current Limit Trip Selection
Jumper Set to TRIPSEL OCP Limit per Phase(Typ.)
Top (1-2 pin shorted) 5VFILT 29A
Second (3-4 pin shorted) 3.3VBIAS 24A
Third (5-6 pin shorted) VREF 20A
Bottom(7-8 pin shorted) GND 17A
5.2 Frequency Selection (J7: TON Select)
The operating frequency can be set by J7 TON Select (TONSEL).
Default setting is 300 kHz.
Table 3. Frequency Selection
Jumper Set to TONSEL Frequency (kHz)
Top (1-2 pin shorted) 5VFILT 500
Second (3-4 pin shorted) 3.3VBIAS 350
Third (5-6 pin shorted) VREF 300
Bottom(7-8 pin shorted) GND 250
5.3 Overshoot Reduction Selection (J9: OSRTM Select)
The overshoot reduction can be set by J9 OSRTM Select (OSRSEL).
Default setting is Maximum.
Table 4. Overshoot Reduction Selection
Jumper set to OSR Overshoot Voltage Reduction
Top (1-2 pin shorted) 5VFILT OFF
Second (3-4 pin shorted) 3.3VBIAS Minimum
Third (5-6 pin shorted) VREF Medium
Bottom (7-8 pin shorted) GND Maximum
5.4 VID Bits Selection(S1)
The output voltage can be set by Switch S1 (VID Bits).
Default setting is 000.
Table 5. VID Bits Selection
3-Bit VID Table (1 = 1VBIAS, 0 = GND)
VID2 VID1 VID0 Vout (V)
0 0 0 1.05
0 0 1 1.00
0 1 0 0.95
0 1 1 0.90
1 0 0 0.85
1 0 1 0.80
1 1 0 0.75
12
Using the TPS51513EVM-549 A Single-Phase, D-CAP+™ Synchronous Buck SLVU358February 2010
Controller With Integrated Drivers for General IC V
CORE
Applications
Submit Documentation Feedback
Copyright © 2010, Texas Instruments Incorporated