Datasheet

www.ti.com
Configurations
5 Configurations
Make all Switcher selections before applying power to the EVM. Configure this EVM per the following:
Enable1 Selection
The EN1 pin can be set by S1.
Default setting: S1 to OFF to disable the Output1
Table 2. EN1 Selection
Switcher set to SKIPSEL Selection
ON Enable the Output1
OFF Disable the Output1
Enable2 Selection
Default setting: S2 to OFF to disable the Output2
Table 3. EN2 Selection
Switcher set to Enable Selection
ON Enable the Output2
OFF Disable the Output2
6 Test Procedure
6.1 Line/Load Regulation and Efficiency Measurement Procedure
1. Set up the EVM as described in Section 4 and Figure 3
2. Ensure Load1 and Load2 are set to constant resistance mode and to sink 0 Adc
3. Ensure the configuration settings per Section 5
4. Ensure S1 and S2 are in the OFF position before Vin is applied
5. Increase Vin from 0 V to 12 V. Using V1 to measure input voltage
6. Switch S1 to the ON position to enable the Output1
7. Use V2 to measure Vout1 voltage
8. Vary Load1 from 0–10 Adc, Vout1 should remain in load regulation
9. Vary Vin from 8 V to 20 V, Vout1 should remain in line regulation
10. Switch S1 to the OFF position to disable the Output1
11. Switch S2 to the ON position to enable the Output2
12. Use V3 to measure Vout2 voltage
13. Vary Load2 from 0–10 Adc, Vout2 should remain in load regulation
14. Vary Vin from 8 V to 20 V, Vout2 should remain in line regulation
15. Switch S2 to the OFF position to disable the Output2
16. Decrease Load1 and Load2 to 0 A
17. Decrease Vin to 0 V