Datasheet

TI Information Selective Disclosure
TPS51116
www.ti.com
SLUS609I MAY 2004REVISED JANUARY 2014
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
Supply voltage, V5IN, V5FILT 4.75 5.25 V
VBST, DRVH –0.1 34
LL –0.6 28
VLDOIN, VTT, VTTSNS, VDDQSNS –0.1 3.6
Voltage range V
VTTREF –0.1 1.8
PGND, VTTGND, CS_GND –0.1 0.1
S3, S5, MODE, VDDQSET, CS, COMP, PGOOD,
–0.1 5.25
DRVL
Operating free-air temperature, T
A
–40 85 ° C
Copyright © 2004–2014, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: TPS51116