Datasheet

Setup
www.ti.com
The following listing describes the functions of the various test points.
Test Points
EN1 Enable for switcher 1
EN2 Enable for switcher 2
EN3 Enable for switcher 3
EN4 Enable for the linear regulator
EXTSUP External power source for the MOSFETs
GND (x9) Ground
PH1 Switcher 1 phase pin
PH2 Switcher 2 phase pin
PH3 Switcher 3 phase pin
RST1 Reset output for switcher 1
RST2 Reset output for switcher 2
RST3 Reset output for switcher 3
RST4 Reset output for the linear regulator
VBAT Power Input
VIN Power Input after the reverse battery protection diode
VINLR1 Linear regulator input
VOUT1 Switcher 1 output
VOUT2 Switcher 2 output
VOUT3 Switcher 3 output
VOUT4 Linear regulator output
VSUP Power input for switcher 3
2.2 Setup
The input voltage range for the converter is 4 V to 40 V. The minimum input voltage is 6.5 V at start-up.
The input voltage range is 4 V to 10 V for switcher 3.
2.3 Operation
For the correct operation of the TPS4334xEVM, Delay, EN1, EN2, EN3, EN4, EXTSUP, JP1, JP5, JP6,
PGATE, and VIN2, must be properly configured. The recommended setting, using the switch and shorting
blocks, follow.
Delay 1 ms
EN1 Disabled
EN2 Disabled
EN3 Disabled
EN4 Disabled
EXTSUP VOUT1
JP1 Auto
JP5 External supply
ROSC 400 kHz
SLEW Fast
SYNC Forced continuous conduction mode
VIN2 VIN
VINLR1 VIN
6
TPS4334xEVM Evaluation Module SLVU463July 2011
Submit Documentation Feedback
Copyright © 2011, Texas Instruments Incorporated