Setup
S3 – Control Switch is a seven position DIP switch used to set the operating frequency, enable the
external clock and control Switcher 1, Switcher 2, the switched linear regulator, and the high-side switch.
Figure 1. Control Switch Diagram
FS0, FS1, and CLKEN – Set the frequency and to enable the preprogrammed external clock from the
MSP430 to the TPS43331 Synch input. The TPS43331 internal clock source is also used if the No Clock
setting is selected. The user can also apply an optional user defined external clock to the CLK test point, if
the User Defined setting is selected.
Table 2. SYNCH Frequency Select and Enable Switch Settings
Clock Frequency FS0 FS1 CLKEN
No Clock Position 2 Position 2 Don't care
250 kHz Position 1 Position 2 Position 2
333 kHz Position 2 Position 1 Position 2
400 kHz Position 1 Position 1 Position 2
User Defined Don't care Don't care Position 1
The frequency is set when power is applied to the EVM and cannot be changed after power-up. Set the
switch to the desired frequency before applying power to the EVM.
The jumpers can also be used to disable the MSP430 during EMC testing. The procedure to disable the
MSP430 is:
1. Set FS0 and FS1 to the No Clock setting before power up.
2. Apply power to the EVM.
3. Set the regulator conditions on the TPS43331 to be tested.
4. Set FS0 and FS1 to Position 1 to disable the MSP430.
NOTE: Power must to cycled to the EVM to turn the MSP430 back on and send new commands to
the TPS43331 after EMC testing has been completed.
SW1EN – Used to control Switched Regulator 1 on the TPS43331. The switch can be moved at any time
after power has been applied to the EVM. All regulators (except for the standby regulator) are disabled if
Switcher 1 is disabled.
Table 3. Switched Regulator 1 Switch Setting
Switcher 1 SW1EN
Disabled Position 1
Enabled Position 2
3
SLVU349–October 2009 TPS43331EVM
Submit Documentation Feedback