Datasheet
1
2
3
4
8
7
6
5
VDD
ISNS
GDRV
GND
RC
SS
COMP
FB
TPS40200
R
SENSE
V
IN
V
OUT
R1 R2
L1
C2
D1
C1
C3
C4
C5
C6
R4
R3
R5
Q1
50
60
70
80
90
100
0 0.5 1 1.5 2 2.5 3
LoadCurrent- A
Efficiency-%
V =8V
V =12V
V =16V
IN
IN
IN
V =5V
OUT
TPS40200-EP
SGLS371A –JANUARY 2007–REVISED JANUARY 2013
www.ti.com
This integrated circuit can be damaged by ESD. Texas Instruments recommends that all integrated circuits be handled with
appropriate precautions. Failure to observe proper handling and installation procedures can cause damage.
ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more
susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.
TYPICAL APPLICATION
Figure 1. 12-V to 5-V Buck Converter Figure 2. Typical Efficiency of Application Circuit 1
(Described in Application 1)
With 94% Efficiency
ELECTROSTATIC DISCHARGE (ESD) PROTECTION
MIN MAX UNIT
Human-Body Model 1000 V
CDM 1500 V
ABSOLUTE MAXIMUM RATINGS
(1)
over operating free-air temperature range (unless otherwise noted)
UNIT
V
DD
, ISNS 52
Input voltage range RC, FB –0.3 to 5.5 V
SS –0.3 to 9
COMP –0.3 to 9
Output voltage range V
GDRV (V
IN
– 10) to V
IN
T
J
Operating virtual junction temperature range –55 to 150 °C
T
stg
Storage temperature range –55 to 150 °C
Lead temperature 1,6 mm (1/16 in) from case for 10 s 260 °C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
RECOMMENDED OPERATING CONDITIONS
MIN MAX UNIT
V
DD
Input voltage 4.5 52 V
2 Submit Documentation Feedback Copyright © 2007–2013, Texas Instruments Incorporated
Product Folder Links: TPS40200-EP