5.3 Start-up/Shutdown Procedure
5.4 Output Ripple Voltage Measurement Procedure
Test Setup
Figure 4. TPS40193EVM-001 Control Loop Measurement Setup
Follow these steps to start up and shut down the TPS40193EVM-001.
Step 1. Increase V
IN
from 0V to 12V
DC
.
Step 2. Vary LOAD1 from 0A
DC
to 10A
DC
.
Step 3. Vary V
IN
from 8.0V
DC
to 14V
DC
.
Step 4. Decrease V
IN
to 0V
DC
.
Step 5. Decrease LOAD1 to 0A.
Follow these steps to measure the output ripple voltage on the TPS40193EVM-001.
Step 1. Increase V
IN
from 0V to 12V
DC
.
Step 2. Adjust LOAD1 to desired load between 0A
DC
and 10A
DC
.
Step 3. Adjust V
IN
to desired load between 8.0V
DC
and 14V
DC
.
Step 4. Connect oscilloscope probe to TP15 and TP16 as shown in Figure 3 .
Step 5. Measure output ripple.
Step 6. Decrease V
IN
to 0V
DC
.
Step 7. Decrease LOAD1 to 0A.