5 Test Set Up
5.1 Recommended Test Equipment
5.1.1 Voltage Source
5.1.2 Meters
5.1.3 Loads
Test Set Up
Figure 2. TPS40180EVM Configuration Schematic
The input voltage source V
IN
should be a 0–15 V variable DC source capable of 10 A. Connect V
IN1
to J1
as shown in Figure 3 .
The input voltage source V
IN2
should be a 0–6 V variable DC source capable of 2 A. Connect V
IN2
to J2 as
shown in Figure 3 .
V1: V
IN
0–15 V voltmeter
V2: V
OUT
0–5 V voltmeter
I1: I
IN
, 0–10 A current meter
The output load (LOAD) should be an electronic constant current mode load capable of 0–30 A DC at 1.5
V.
SLVU213 May 2007 Using the TPS40180EVM, A 20A Stackable Single Phase Synchronous Buck Converter 5